
Farms & Rural Properties
Store harvested produce, meat and food supplies closer to where you work.
Discuss your site
Solar + Battery.
Automatic Generator Backup.
Containerised chilled or frozen storage for farms, fisheries and remote sites.
An insulated cold room keeps your goods separate from the electrical equipment bay.
Explore the interior, with space planned for stock, access and airflow.

From the farm gate to the remote worksite, plan cold storage around the way you operate.

Store harvested produce, meat and food supplies closer to where you work.
Discuss your site
Chilled or frozen storage for seafood at landing points and remote facilities.
Discuss your site
On-site food storage for teams working beyond a reliable electricity supply.
Discuss your site
Containerised cold storage for temporary operations and essential supplies.
Discuss your siteApplication visualisations
Fresh produce, held close to harvest.
Illustrative scenes. Set temperature to suit your goods.
Solar first. Battery when needed. Generator backup when required.
Two container sizes. The same integrated solar, battery and generator approach.

Internal cold room volume
6.058 × 2.438 × 2.896 m L × W × H · Container exterior
For projects with a smaller storage requirement or limited site space.
Discuss 20ft
Internal cold room volume
12.192 × 2.438 × 2.896 m L × W × H · Container exterior
For projects with a larger storage requirement.
Discuss 40ftModel views use a matched camera scale. Container dimensions exclude solar arrays and required installation clearances.
| Specification | 20ft Configuration | 40ft Configuration |
|---|---|---|
| Container type | 20ft High Cube | 40ft High Cube |
| External dimensions (L × W × H) | 6.058 × 2.438 × 2.896 m | 12.192 × 2.438 × 2.896 m |
| Internal cold room dimensions | 4.68 × 2.16 × 2.47 m | 10.52 × 2.16 × 2.47 m |
| Internal cold room volume | 24.9 m³ | 56.0 m³ |
| Temperature range | −18°C to +6°C | −18°C to +6°C |
| Solar PV capacity | 9.9 kWp | 10.56 kWp |
| Battery storage | 48 kWh LiFePO₄ | 48 kWh LiFePO₄ |
| Hybrid inverter | 11 kW | 11 kW |
| Generator with automatic transfer | 5.5 kW with ATS | 5.5 kW with ATS |
| Insulation thickness | 100 mm | 100 mm |
Internal room volume excludes insulation and the equipment compartment. Allow additional space for the evaporator, access aisles and product stacking. Final configuration and performance are subject to project confirmation.
20ft and 40ft specifications, system configuration and a site-planning checklist.

Equipment layout varies by configuration.
Insulated walls, ceiling and floor help reduce heat transfer into the storage space.
The electrical equipment bay is physically separated from the cold room.
An internal safety release and PVC strip curtain support practical day-to-day access.
Set one storage compartment to the temperature your goods require.
Plan the practical details before your cold room arrives.
Level foundation, drainage and access for delivery.
Plan freight, lifting and container placement.
Assemble the solar structure and complete connections.
Test operation and set the storage temperature.
Freight, lifting, installation and support responsibilities.
Share your location, site access and preferred room size.Have a site-specific question? Tell us where you operate and what you need to store.
Talk about your projectYes. The system integrates solar panels, battery storage and a diesel backup generator for operation without a mains connection. The final configuration should be checked against your location and cooling requirements.
The battery supports operation when solar output is low or unavailable. When required, the generator starts automatically to support refrigeration or recharge the battery.
Battery runtime depends on ambient temperature, the set temperature, stored goods, incoming product temperature and door-opening frequency. Share your operating conditions for a project-specific assessment.
The standard unit has one cold storage compartment, adjustable from −18°C to +6°C. It is not a simultaneous dual-temperature room. Select a setting appropriate for your goods.
Provide a level, load-bearing foundation, suitable drainage and access for delivery and lifting. Allow space for the solar array, ventilation and maintenance. Installation includes solar structure assembly, connections and commissioning.
Remote monitoring is optional. The monitoring package can collect temperature and energy data and provide alerts. Connectivity and any external satellite terminal or subscription are confirmed separately.
Consider the goods you store, the space required for access and airflow, and your daily incoming stock. Share your requirements and we can discuss the appropriate configuration.
The proposed configuration brings together the containerised cold room, refrigeration, solar panels, battery storage, hybrid inverter and generator backup. Equipment and scope are confirmed in your project quotation.
Delivery is assessed for each site. Road access, lifting arrangements, foundations, location and the final installation scope need to be confirmed.
Contact our team for the applicable warranty terms and to discuss servicing arrangements for your location and configuration.
Cooling needs depend on the type and quantity of produce, incoming temperature, target temperature and daily loading. Share these details so the system can be assessed for your application.
Tell us where you operate and what you need to store. Our team can help you explore the right configuration for your site.
Share what you store, how much arrives each day and your target temperature. This helps us discuss room size, cooling demand and the work required at your site.
Download the product guide